Review



langendorff perfusion flow apparatus (including bubble trap) 120106ez/s-v  (Radnoti LLC)

 
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    Radnoti LLC langendorff perfusion flow apparatus (including bubble trap) 120106ez/s-v
    Langendorff Perfusion Flow Apparatus (Including Bubble Trap) 120106ez/S V, supplied by Radnoti LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/langendorff+perfusion+apparatus/non+circulating+langendorff+apparatus/pmc12002646-28-10-8
    Average 90 stars, based on 1 article reviews
    langendorff perfusion flow apparatus (including bubble trap) 120106ez/s-v - by Bioz Stars, 2026-09
    90/100 stars

    Images

    Related Articles

    Isolation:

    Article Title: Intrinsic cardiac adrenergic cells contribute to LPS-induced myocardial dysfunction
    Article Snippet: Myocardial functions of adult rats were measured using a Langendorff perfusion system as we previously described.4 Briefly, the Sprague-Dawley rats (8-10 weeks, 250-300 g) were heparinized (i.p. injection heparin, 2000 U) for 15 min, and then deeply anesthetized with isoflurane inhalation (3% isoflurane in 100% oxygen at a flow rate of 1 L/min). .. The hearts were isolated, and then the aortas were retrograde set up to a Langendorff perfusion apparatus (Radnoti Langendorff system#120102EZ) to perfuse at 10mL/min with Krebs-Henseleit buffer containing (in mM) 118 NaCl, 4.7 KCl, 25 NaHCO3, 1.2 KH2PO4, 1.2 MgSO4, 2.5 CaCl2 and 11 glucoses (bubbled with 95% O2 and 5% CO2 gas mixture and maintained at 37 °C). ..

    Article Title: Intrinsic cardiac adrenergic cells contribute to septic cardiomyopathy
    Article Snippet: Briefly, the Sprague-Dawley rats (8-10 weeks) were heparinized (i.p. injection heparin, 2000 U) for 15 min, and then deeply anesthetized with isoflurane inhalation (3% isoflurane in 100% oxygen at a flow rate of 1□L/min) using a face mask. .. The heart was isolated and the aorta was retrograde set up to a Langendorff perfusion apparatus (Radnoti Langendorff system#120102EZ) with a recirculating mode (volume of 50 mL) to perfuse at 10mL/min with Krebs-Henseleit buffer (bubbled with 95% O2 and 5% CO 2 gas mixture and maintained at 37 °C). .. Rat hearts were divided into groups of K-H buffer (control, n=7) and LPS (Sigma-Aldrich, #L2880, Escherichia coli, 055:B5, 1.5 μg/mL) (n=7).

    Article Title: Intrinsic cardiac adrenergic cells contribute to LPS-induced myocardial dysfunction
    Article Snippet: Briefly, the Sprague-Dawley rats (8–10 weeks) were heparinized (i.p. injection heparin, 2000 U) for 15 min, and then deeply anesthetized with isoflurane inhalation (3% isoflurane in 100% oxygen at a flow rate of 1 L/min) using a face mask. .. The hearts were isolated and the aortas were retrograde set up to a Langendorff perfusion apparatus (Radnoti Langendorff system#120102EZ) with a recirculating mode (volume of 50 mL) to perfuse at 10 mL/min with Krebs-Henseleit buffer (bubbled with 95% O 2 and 5% CO 2 gas mixture and maintained at 37 °C). .. Rat hearts were divided into groups of K-H buffer (control) or LPS (Sigma-Aldrich, #L2880, Escherichia coli, 055: B5, 1.5 μg/mL).

    other:

    Article Title: Conduction delays across the specialized conduction system of the heart: Revisiting atrioventricular node (AVN) and Purkinje-ventricular junction (PVJ) delays
    Article Snippet: Hearts were excised from the chest and perfused in a Langendorff perfusion apparatus (Radnoti LLC, Covina CA).

    Ex Vivo:

    Article Title: Injectable conductive hydrogel restores conduction through ablated myocardium.
    Article Snippet: .. A large animal Langendorff perfusion apparatus (Radnoti) was used to perfuse the heart ex vivo in a warmed basin (Figure 1).14 The hearts were perfused with a modified Krebs–Henseleit solution which was oxygenated with 95% O2 and buffered to 5% CO2. .. 15 The perfusate solution consisted of the following: NaCl (118mmol/L), NaHCO3 (25mmol/L), mannitol (16mmol/L), D‐glucose (11mmol/L), KCl (4.7mmol/L), sodium pyruvate (2.3mmol/L), CaCl2 (2.0mmol/L), KH2PO4 (1.18mmol/L), MgSO4 (1.17mmol/L), and human insulin (10U/L; Novolin; Novo Nordisk).

    Modification:

    Article Title: Injectable conductive hydrogel restores conduction through ablated myocardium.
    Article Snippet: .. A large animal Langendorff perfusion apparatus (Radnoti) was used to perfuse the heart ex vivo in a warmed basin (Figure 1).14 The hearts were perfused with a modified Krebs–Henseleit solution which was oxygenated with 95% O2 and buffered to 5% CO2. .. 15 The perfusate solution consisted of the following: NaCl (118mmol/L), NaHCO3 (25mmol/L), mannitol (16mmol/L), D‐glucose (11mmol/L), KCl (4.7mmol/L), sodium pyruvate (2.3mmol/L), CaCl2 (2.0mmol/L), KH2PO4 (1.18mmol/L), MgSO4 (1.17mmol/L), and human insulin (10U/L; Novolin; Novo Nordisk).



    Similar Products

    90
    Radnoti LLC langendorff perfusion flow apparatus (including bubble trap) 120106ez/s-v
    Langendorff Perfusion Flow Apparatus (Including Bubble Trap) 120106ez/S V, supplied by Radnoti LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/langendorff+perfusion+apparatus/non+circulating+langendorff+apparatus/pmc12002646-28-10-8
    Average 90 stars, based on 1 article reviews
    langendorff perfusion flow apparatus (including bubble trap) 120106ez/s-v - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Radnoti LLC langendorff perfusion flow apparatus (including bubble trap)
    Langendorff Perfusion Flow Apparatus (Including Bubble Trap), supplied by Radnoti LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/langendorff+perfusion+apparatus/non+circulating+langendorff+apparatus/pm40188432-79-111-120
    Average 90 stars, based on 1 article reviews
    langendorff perfusion flow apparatus (including bubble trap) - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    93
    ADInstruments constant perfusion pressure apparatus
    Constant Perfusion Pressure Apparatus, supplied by ADInstruments, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/langendorff+perfusion+apparatus/Radnoti+Rat+Langendorff+Constant+Pressure+Apparatus/bio_rxiv__2025__02__24__639999-88-2-6
    Average 93 stars, based on 1 article reviews
    constant perfusion pressure apparatus - by Bioz Stars, 2026-09
    93/100 stars
      Buy from Supplier

    90
    ADInstruments langendorff perfusion apparatus
    Langendorff Perfusion Apparatus, supplied by ADInstruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/langendorff+perfusion+apparatus/langendorff+apparatus/10__1113_slash_jp286453-115-29-32
    Average 90 stars, based on 1 article reviews
    langendorff perfusion apparatus - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Reichelt Chemietechnik langendorff perfusion apparatus
    Langendorff Perfusion Apparatus, supplied by Reichelt Chemietechnik, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/langendorff+perfusion+apparatus/langendorff+perfused+mouse+heart+model/pm36951040-104-11-23
    Average 90 stars, based on 1 article reviews
    langendorff perfusion apparatus - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    Image Search Results